Esophagus
|
AP or PA
IR Size: 14x17 LW
SID: 40""
Page #'s: 2:120,230
|
Positioning:
• Pt supine/prone
|
CR Entrance & Angle:
• _|_ to center of IR
•
Collimation:
•
|
Eval Criteria:
• Entire esophagus over spine
• Esophagus filled with barium
• Esophagus from lower part of neck to esophagogastric junction
|
|
PA oblique RAO (LPO)
IR Size: 14x17 LW
SID: 40""
Page #'s: 2:120,232
|
Positioning:
• Pt supine/prone
• MSP rotated 35°-40° (RAO preferred) (Shows unobstructed view b/w vertebrae & heart)
• Shoulders in same plane
|
CR Entrance & Angle:
• _|_ to elevated side ~2"" lateral of MSP
•
Collimation:
•
Best to Determine:
• Best view of esophagus
|
Eval Criteria:
• Esophagus b/w heart shadow & spine
• Esophagus filled with barium
• Esophagus from lower part of neck to esophagogastric junction
|
|
Lateral R/L
IR Size: 14x17 LW
SID: 40""
Page #'s: 2:120,234
|
Positioning:
• Pt faces radiographer
• Arms forward
|
CR Entrance & Angle:
•
•
Collimation:
•
|
Eval Criteria:
• NR by Ribs posterior to spine SI
• Esophagus filled with barium
• Esophagus from lower part of neck to esophagogastric junction
|
|